Linear Orifice Flow Meter Variable Description Table: in order of appearance in code
Variable Name |
Variable Description |
|---|---|
![]() |
Number of riser pipes |
![]() |
minor loss coefficient for rapid mix |
![]() |
Combined area of all orifices |
![]() |
function for determining the orifice areas as the vertical distance on the riser pipe increases |
![]() |
headloss through the Lfom, and the minimum height of the water in the entrance tank |
![]() |
minor loss coefficient for an orifice (was K orifice) |
![]() |
plant flow rate |
![]() |
the inner diameter of the riser pipe |
![]() |
ratio of LFOM pipe area to orifice area |
![]() |
nominal diameter of the riser pipe and rapid mix pipe |
![]() |
enumerated type of pipe |
![]() |
rapid mix head loss |
![]() |
The total pipe length betweeen the bottom of the orifices and the flocculator |
![]() |
viscosity of water through the plant |
![]() |
PVC pipe roughness |
![]() |
Function based off of ramp functions, this is an incremental function that all ows other funtions to evaluate one level of orifices at a time |
![]() |
vertical distance between orifices |
![]() |
elevation between orifice rows at which the flow is calibrated, a 0 or 1 value. 0 corresponds to the current row and 1 corresponds to the next row |
![]() |
funtion to determine target riser pipe flow, incrementally calculates flows |
![]() |
funtion to determine actual flow through orifices |
![]() |
number of orifices |
![]() |
diameter of Lfom orifices |
![]() |
function that determines the diamter of a circle given the area |
![]() |
function that determines the drill bit size necessary |
![]() |
arbitrary value determines the number of orifices in the first row, currently 5 is selected |
![]() |
percent error in the actual flow rate compared to theoretical values |
![]() |
maximum error of Q_LfomError array |
![]() |
headloss from the entrance tank to the flocculator |
![]() |
water depth of entrance tank relative to the bottom of the sedimation tank |
![]() |
height of the start of the floculation tank relative to the bottom of the sedimention tank |
![]() |
difference between height of water in floculation tank and the bottom set of orifices on the LFOM |
![]() |
maximum water level in entrance tank |
![]() |
minimum water level in entrance tank |
![]() |
height of entrance tank walls |
![]() |
height of entrance tank above the top of the riser pipe |
![]() |
safety factor of height of riser pipe above top row of orifices |
![]() |
height of the riser pipe |