Pre-Analysis & Start-Up

Pre-Analysis

In the Pre-Analysis step, we'll review the following:

  • Governing Equations: We will review the governing equations that need to be solved in this problem.
  • Boundary Conditions: We will go into more details about the boundary conditions that are applied in this problem.

Governing Equations   

Since we are neglecting the convection terms, the diffusion equation we want to use looks nearly identical to the heat equation. Therefore, we can solve the heat equation with the flow terms disabled and then simply reinterpret the results as if we had solved the diffusion equation.

Boundary Conditions

Outer Boundary:

The outer boundary will be set to “wall”. Then we will set a zero-flux boundary condition, which corresponds to an impermeable wall when discussing diffusion.

Axis:

The horizontal boundary will be set to "axis" which will tell Fluent that the domain Note that Fluent only allows axisymmetric rotation about the x-axis.

Symmetry:

The outer boundary will be set to “wall”. Then we will set a zero-flux boundary condition, which corresponds to an impermeable wall when discussing diffusion.

 

Please see the hand out below for more details:

 

Go to Step 2: Geometry

Go to all FLUENT Learning Modules

  • No labels