h1. Automated Chemical Doser Design
{float:right|border=2px solid black|width=260px}
[!Laboratory Research Set-ups^Labeled Robust ACD freestanding F08 2.JPG|width=260px!|Laboratory Research Set-ups]
{float}
The automated chemical doser (ACD) has three principles components: a float, a lever arm, and a [flow controller|Flow Controller] (FCM).
The float is a 45.5cm long 4in PVC tube capped at both ends and partially filled with sand so that it weighs 8lbs. It rests 33.5cm below and 12cm above the water line in a virtual grit chamber, which is a deep bucket with a pressure sensor at its base. This pressure sensor provides readings of the water level in the bucket.
\\
{float:left|border=2px solid black|width=260px}
[!Laboratory Research Set-ups^IMG_7223.JPG|width=260px!|Laboratory Research Set-ups]
{float}
\\