One idea we got from Fred Stottlemeyer is to drill holes in the lamella large enough to put 1/2¨PVC tube through them, but small enough so that the tube fits snugly. We would then put a short nipple through the hole and put a PVC union on each side of the nipple. We´d squeeze the unions together so that the made a tight sandwich around the lamina. The unions are 4.1 cm (about 5 cm) so we´re thinking we could probably just use one union between each floc lamella.
We´re going to try Fred´s method of the union sandwiches out soon. Concerns are that the holes will be hard to drill and that the unions will not be thick enough to securely detain the lamina. The unions might slip through the holes.
{float:right|border=2px solid black|width=310px}
{anchor:Ojojona assembly}[!Modular plate settler^4cmspacing.png|width=300!|Modular plate settler^4cmspacing.png]
h5. Proposed assembly technique for the plate settlers giving 4 cm spacing.
{float} |
We think we have a good solution to the plate settler issue. We tried Fred`s suggestion of using the 1/2" PVC unions as spacers and connecting them with short nipples of 1/2" pipe. It worked very well. Concerns that we had discussed were:
The unions that we want to use as spacers are only 4 cm in length. This would mean smaller gaps between the sed lamella. I think I remember Fred saying that usually lamella spacing is smaller than 4 cm and that this might give improved performance. Of course it would also mean more lamella. Instead of buying 60 12-foot polciarbonate sheets for the plant (floc and sed), it would mean buying 72 sheets. At a cost of 900L a sheet, this is 10,800 L or about $550, but still much less than what we´ll save by not buying CPVC caps. We had another idea to make the spacers 5 cm: cut 1cm rings from unions and put them together with the full unions. This would work but we think it will be difficult to cut the rings uniforly to 1 cm. If the 4cm spacing will work just as well or better we recommend going with that. The two options are drawn in the attached power point.
{float:right|border=2px solid black|width=310px}
{anchor:Ojojona assembly}[!Modular plate settler^5cmspacing.png|width=300!|Modular plate settler^5cmspacing.png ]
h5. Proposed assembly technique for the plate settlers giving 5 cm spacing.
{float} |
We`re also discussing how many spacers to put in the sed modules. In the same attached file is a diagram of three different posibilities. We tried the 7 spacer option and it looked alright but we thought it would be worth adding more. The 8 spacer option, with the middle row staggered looks the strongest to us, even better than the 9 spacer option. One possible concern is that the 8 spacer option blocks more of the path through the lamella with spacers, since they are in 5 different horizontal positions. To us this seems insignificant. Are you in agreement?
{float:right|border=2px solid black|width=310px}
{anchor:Ojojona assembly}[!Modular plate settler^connectorpattern.png|width=300!|Modular plate settler^connectorpattern.png]
h5. Proposed pattern of connectors.
{float} |