The goal of our research is to evaluate the feasibility of a siphon-aided backwash design to be used for a sand or mixed-media down-flow filter. The benefits of siphon-aided backwash are:
1) The height of the clear-well does not need to be equal to the the head pressure required to attain 30%-50% expansion.
2) The filter bed can be right next to the clear-well, connected via an open pipe without a valve. Flow of water into and out of the clear-well will be controlled by valves on the influent and backwash manifolds.
3) Using 55 gallon HDPE barrels, we will create a system of parallel filters surrounding a shared clear-well. By backwashing the filters out of phase, we will reduce the demand for a large clear-well. Additionally, the downflow filters will be filling the clear-well while the other filters being backwashed draw from it. This allows faster clear-well recharge rates and shortens the time between consecutive backwash cycles.
An example of a patented siphon-aided backwash design (Automatic Valveless Gravity Filter)
The filter bed rests inside an air-tight container. The influent enters through a port above the sand bed. The siphon is also connected through a separate port, connected to the container, above the sand bed. The clean water exits the container below the sand bed, which leads to clear-well storage.
Flow scheme in regular down-flow mode:
Raw water enters from the top>sand bed>out to clear-well
In backwash mode: The siphon is "primed" by the headloss generated in the clogging filter, which causes the raw water to flow up the siphon tube. Eventually the water begins to flow over the bend of the siphon and as it fills the tube, a negative pressure gradient is established, diverting all flow out the siphon.
Water from clear-well flows in reverse>sand bed (from bottom)>siphon>waste
Concentric well screen filter design
Offset filter bed design
55 Gallon Barrel Filters with Shared Clear Well
Single 55 gallon barrel filter schematic
Height required to attain backwash velocity (with headloss calculations)
a. Sand level monitoring
b. Pressure across filters
c. Flow distribution during backwash
d. Bypass entire system
a. 7 backwash 1 problems/feasibility
b. Inclusion of clear well
c. Backwash with raw water
Bench top model:
-Test how changing the height difference influences backwash velocities.
-Fine-tune the backwash velocity using a gate valve on the siphon tube.