Linear Flow Orifice Meter Equations

Total Flow Rate Through Weir

Unknown macro: {latex}

$$ Q = c [h +

Unknown macro: {2 over 3}

s] $$

The constant of proportionality, c :

Unknown macro: {latex}

$$ c = W k {s^{1 \over 2}} $$

The variable k :

Unknown macro: {latex}

$$ k = 2 C_d \sqrt

Unknown macro: {2g}

$$

Combined and substitued :

Unknown macro: {latex}

$$ Q = W 2 C_d \sqrt

Unknown macro: {2g}

{s^{1 \over 2}} [h +

Unknown macro: {2 over 3}

s] $$

Flow Through Rectangular Base of Weir

Unknown macro: {latex}

$$ q_w =

Unknown macro: {4 over 3}

W C_d \sqrt

Unknown macro: {2g}

[{{(h + s)}^{2 \over 3}} - {h^{2 \over 3}}] $$

Rectangular Base Height

Unknown macro: {latex}

$$ s =

Unknown macro: {3 over 2}

\Pi_

Unknown macro: {sutro}

H_

Unknown macro: {dmax}

$$

Profile of Curved Portion

Unknown macro: {latex}

$$ y =

Unknown macro: {W over 2}

[1 -

Unknown macro: {s over Pi}

tan^{-1} \sqrt

Unknown macro: {x over s}

]$$