Figure 1 shows the boundary conditions of the flocculation tank. The top part of the flocculation is open, so a symmetry boundary conditions is employed. Set the inlet boundary condition to inlet velocity of 0.1 m/s. Outlet condition is set to pressure outlet. 

Table 1. Boundary conditions

Boundary

Boundary Conditions

Top

Symmetry

Wall

Wall

Inlet

Velocity Inlet (0.1m/s)

Outlet

Pressure Outlet

...