Spiral Tubing Design

Summary

One of the proposed designs for incorporating the alum doser was to use long, spiraled tubing that connects the alum stock to the influent water entering the filter. Calculations were done in order to determine the parameters associated with the spiral tubing. Unfortunately, it was discovered that in order for this design to work, the exit tubing would need to be approximately 8 3.5 meters in length. This is too large for the desired size of our unit.

Calculations

Download the Spiral Tubing Design MathCAD File here.

The user inputs the maximum turbidity (used to determine the alum dose concentration), the desired flow rate of alum (converted to liters/day), and the diameter of tubing, which is used to determine the area of tubing. The inner diameters of available tubing can be found on McMaster-Carr: http://www.mcmaster.com/#tubing/=bdk5q3.

...

Given the length of tubing, we determine the number of spirals needed and the circumference of the bucket in which the spirals will be wrapped around. Then, based on the thickness (or outer diameter) of the tubing, the total thickness or height when all the spirals are touching is calculated to ensure that the thickness is less than the user-thickness. If this is the case, the spacing between each spiral is calculated for extra constructability information.

Download the Spiral Tubing Design MathCAD File here

Again, it should be stated that this design would not work well with our point-of-use unit. The tubing length of 3.5 meters is too long and almost ridiculous to include in our filtration system. We can most definitely find a better way to design this component.