Bubble Volume Measurement Method Development
Procedure
| Wiki Markup |
|---|
h1. Results and Discussion of Initial Experiments {float:right|border=2px solid black}[!SandFilterSetup1SandFilterSetup2.png|hspace=5,width=300px600px!|InitialFirst Sand Filter Setup] {float} These are the results of the first several experiments run, with the [initial with Bubble Collector] h5. First version of the experimental setup|Initial Sandthat Filterincluded Setup].a This setup consisted of the flow accumulator and vertical glass filter column. A dissolved oxygen (DO) probe in the flow accumulator recorded the dissolved oxygen concentration of the inflowing tap water. The flow rate and temperature of the water was monitored by a pressure sensor and temperature probe inside the flow accumulator and controlled by valves on the hot and cold water lines. These valves were opened and shut by the program _ProcessController_. Once the water had run through the filter column, it was collected in a small beaker containing another DO probe, which recorded the dissolved oxygen concentration of the outflowing water. The first experiment run using the bubble collection method used glass beads as the filter media, with a flow rate of 200 ml/min and an unsuspended filter depth of 32 cm. We observed that the performance of the system increased for about 20 minutes, after which the rate of the increase in air volume became relatively constant. This is illustrated in Figure 1, below. After 20 minutes, the line becomes nearly linear. We concluded that the experiment needs run for at least 20 minutes in order for the data to become steady and reliable. We will start recording data after 20 minutes of runtime. !BubbleVol vs. Time, 200mLmin.png|width=32px,,height=32! *Figure 1* The Bubble Volume collected over time with a flow rate of 200 ml/min and a sand depth of 32 cm. The glass bead are used as the filter media. In Figure 2 (below), we could see that the change in dissolved oxygen that occurs over the span of minutes. The first experiment used a flow rate of 200 ml/min and a sand depth of 32cm. Overall, the DO concentration was lower at the inflow. While the inflow DO concentration was about 9mg/L, the outflow was roughly at 11 mg/L. After taking the difference in DO concentration in inflow and outflow and finding the average DO concentration difference, we corrected the outflow DO concentration. The corrected outflow DO concentration was about little above 9 mg/L. Overall, the Figure 2 showed that with sand depth of 32 cm at 200 ml/min with, the outflow DO concentration was higher than the inflow concentration. This was inconsistent to what was predict. This was probably due to the error in the DO probe. After running the experiment, we noticed that the DO probe was not functioning properly. We concluded that we needed to purchase a new DO probe to measure the concentration or another method to measure the DO concentration. !First Run with glass beads white bg.png|width=32px,,height=32! *Figure 2* The first run with glass beads at 200 ml/min with a sand depth of 32 cm. Since there were problems with the DO probe, we switched to measuring the bubble volume at the outflow. Using MathCad, we used the bubble volume collected to calculate the DO concentration in the outflow water. Next, we experimented with the sand depth. At a flow rate of 200ml/min, we obtained the following result: !Varying glass bead depth 32 10 white bg.png|width=32px,,height=32! *Figure 3* The Effect of varying the Glass Bead Depth at a flow rate of 200 ml/min Figure 3 showed that a sand depth of 10cm is better than the larger sand depth of 32cm. Assuming there was no error in the calculations, errors may be occuring during the experiment. Logically, this result did not make sense. In addition, this result did not go according to our prediction that at a larger depth sand, the DO concentration would be higher. Furthermore, the following results in Figures 4 and 5 (below) obtained at a later date showed that a larger sand depth extracted more DO. !DO Concentration versus time w outlier white bg.png|width=32px,,height=32! *Figure 4* The DO Concentration versus Time. The DO Concentration is calculated from the air volume. !DO concentration vs time wout outlier white bg.png|width=32px height700px,,height=32! *Figure 5* The DO Concentration versus Time. The DO Concentration is calculated from the air volume. This graph is the same as Graph 4 except that this graph excludes the results from the flow rate of 150 ml/min for 33 cm sand depth. Figures 4 and 5 were from the same data except that the bottom graph did not have the results from the flow rate of 150 ml/min for 33 cm sand depth. The results were taken out to show a better view of the other results that overlap each others in the top graph. Moreover, the results obtained from the flow rate of 150ml/min for 33 cm sand depth was extremely different from the other results. This may be due to a error or a series of error.The data collected for Graphs 4 and 5 is given below. *Table 1* This table displays neatly displays all the results from varying flow rates (150 ml/min and 200 ml/min) and varying sand depth (10 cm and 33 cm). !Table date 3809.bmp|width=32px height700px,,height=32! Table 1 had results indicating that the outflow DO concentration was lower than the inflow DO concentration. However, there was a discrepancy in the DO concentration reading. DO concentration calculated from the air volume was very different from the reading from the DO probe at the outflow. The initial DO concentration calculated from the air volume is wrong. This was because even air volume of 0 ml, there was DO in the water. With the air volume calculation was not taken into account. To attain a more reliable results, a new DO probe was necessary. For a better view of the difference in the outflow DO concentration from the DO probe and the outflow DO concentration calculated from air volume, the following four figures (Figures 6-9) were derived. !corr10cm150mlmin.png|width=32px height700px,,height=32! *Figure 6* The DO Concentration either from the DO probe or the air volume calculation versus Time for a sand depth of 10 cm at a flow rate of 150 ml/min. !corr10cm200mlmin.png|width=32px height700px,,height=32! *Figure 7* The DO Concentration either from the DO probe or the air volume calculation versus Time for a sand depth of 10 cm at a flow rate of 200 ml/min. !corr33cm150mlmin.png|width=32px height700px,,height=32! *Figure 8* The DO Concentration either from the DO probe or the air volume calculation versus Time for a sand depth of 33 cm at a flow rate of 150 ml/min. !corr33cm200mlmin.png|width=32px height700px,,height=32! *Figure 9* The DO Concentration either from the DO probe or the air volume calculation versus Time for a sand depth of 33 cm at a flow rate of 200 ml/min. In Figures 6 to 9, the DO concentrations from the DO probe were completely different from the DO concentrations calculated from the air volume. The blue lines represented DO concentrations calculated from the bubble/air volume. The red lines represented the outflow DO concentrations from the DO probe. Figures 6, 7, and 9 showed the DO concentrations calculated from the air volume (blue lines) reached a plateau after 10 minutes. The blue lines in Figures 6, 7, and 9 leveled off like the corresponding DO concentration measured by the DO probe (red lines) in Figures 6, 7, and 9. Figures 6, 7, and 9 have a large distance between the DO concentration from DO probe reading and the DO concentration calculated from the air volume. In Figures 6 and 7, the distance between the red and blue lines was 7 mg/L. For Figure 9, the distance between the red and blue lines was 5 mg/L. This distance was probably due to the initial DO concentration in the water that in not incorporated into the DO concentration calculated from the air volume. Unlike Figures 6, 7, and 9, Figure 8 had the blue line (DO concentration calculated from the air volume) higher than the red line (DO concentration from the DO probe reading). The DO concentration calculated from the air volume looked unreasonable high. Furthermore, the blue line (DO concentration calculated from the air volume) in Figure 8 did not reach a plateau. Instead of reaching a plateau, the blue line in Figure 8 peaked at 10 minutes and decreased rapidly to a lower concentration. This indicated that the high DO concentration was probably caused by the unsettle disturbances in the filter from addition glass beads added to achieve a sand depth of 33 cm. The data collected in the Table 1 displayed relatively in the same range except for Run 3 which could be partially visualized in Figure 8. The air volume collected is very different causing the calculated DO concentration to be extremely high. We thought that it was due to addition of the sand to the sand depth that cause this difference and error. After the first two runs, the sand depth was increased from 10 cm to 33 cm. During this change, the filter was open to the atmosphere and the additional sand created disturbance into the settled sand. The addition of the sand may have cause the filter to gather more bubble and we did not allow the system to have enough time to settle out before running the experiment. From the results collected, there were conflicting data on which sand depth was the optimal. At previous runs, the data showed that the sand depth of 10cm was the optimal. However, in the most recent runs, the data indicated that the sand depth of 33 cm out performed the depth of 10cm. This may be due to how the experiments were run. In the previous runs, the larger sand depth was run first and then the shorter sand depth was run after the longer sand depth. There was a period of rest to vacuum the sand out of the column. However, between the experiments, bubbles remained on the top of sand filter from the previous run. These bubbles settlement may have contributed the error in the data collected. In the most current runs, the short depth was run before the longer sand depth. From the data collect, no concrete conclusion could be drawn and more data was needed. h2. Conclusion We have not yet drawn any final conclusions. We would be able to analyze the system better when most of the problems of the system are fixed and it was improved. The current results collected were not promising and stable. This was due to many problems, such as the DO probe not reading the concentration correctlybubble collector {float} |
Since there were problems with the DO probes we used in the initial experimental setup, we switched to measuring the total volume of the bubbles that form inside the filter column. Using MathCad, we used the bubble volume collected to calculate the equivalent DO concentration removed from the water.
The only changes in the setup were to remove the DO probes and instead feed the water leaving the filter column into an inverted graduated cylinder. This cylinder was filled with water at the start of each run and had its mouth submerged in water. As bubbles formed in the filter media, they flowed out into this cylinder and floated to the top, displacing some water and causing the water level inside the cylinder to fall. The air volume was measured every 10 minutes during each run, using the calibrations on the side of the cylinder.
We also tried a new method of testing the quality of the effluent water, using sugar. The sugar test involved collecting the outflowing water in a clear beaker or cylinder and adding some sugar. As the sugar dissolved in the water, if tiny gas bubbles were seen floating to the surface, the water is still super-saturated with gas and our filter method did not work. If no bubbles were seen, then the water was no longer super-saturated, and it could be assumed that the gases were removed.
Results
| Wiki Markup |
|---|
{float:right|border=2px solid black|width=500px}
{anchor:Figure 1}
!Fig.1, vol vs. time, 32 cm.png|width=500px,align=center!
h5. Figure 1: Total gas volume removed from water vs. time by glass beads. Flow rate: 200 mL/min. Bed depth: 32 cm.
{float} |
The first experiment run using this bubble collection method used glass beads as the filter media, with a flow rate of 200 ml/min and an unsuspended filter depth of 32 cm. We observed that the performance of the system increased for about 20 minutes, after which the rate of the increase in air volume became relatively constant. These results are illustrated in #Figure 1. After 20 minutes, the line of gas volume vs. time becomes nearly linear. We concluded that the experiment needs run for at least 20 minutes in order for the data to become steady and reliable, and that we would start recording data after at least 20 minutes of runtime.
Since the graph for gas volume vs. time is basically linear, we could accurately fit a linear trendline to the data using Excel, as shown in #Figure 1. The slope of this trendline represents the rate that the gas is being removed from the water, in mL/min. This rate can be converted to equivalent mL of gas removed per liter of water running through the filter column by dividing the slope of the line by the flow rate in L/min. #Table 1 summarizes this process for the first run with glass beads.
| Wiki Markup |
|---|
{float:left|border=2px solid black|width=500px}
{anchor:Table 1}
h5. Table 1: Gas removed by glass beads. Depth: 32 cm
||Flow Rate (mL/min)||Slope (mL/min)||Gas Removed (mL/L water)||
|200|.7727|3.86|
{float} |
| Wiki Markup |
|---|
{float:right|border=2px solid black|width=500px}
{anchor:Figure 2}
!Fig.2, vol vs. time, 2 depths.png|width=500px,align=center!
h5. Figure 2: Total gas volume removed from water vs. time by glass beads. Flow rate: 200 mL/min. Bed depths: 32 and 10 cm
{float} |
Next, we experimented with the glass bead depth. obtaining the results shown in #Figure 2. The data in #Figure 2 was treated the same way as for the first trial (#Figure 1), and #Table 2 shows the resulting gas removal for each bed depth in mL of gas per L of water. As can be seen in the table, at a flow rate of 200 mL/min, the filter depth of 10 cm appeared to remove more gas than the larger glass bead depth of 32 cm.
| Wiki Markup |
|---|
{float:left|border=2px solid black|width=500px}
{anchor:Table 2}
h5. Table 2: Gas removed by glass beads at varied depths
||Bed Depth (cm)||Flow Rate (mL/min)||Slope (mL/min)||Gas Removed (mL/L water)||
|10|200|4.9255|24.63|
|32|200|.78|3.9|
{float} |
This did not make sense, so we repeated the experiment later. #Figures 3 and 4 illustrate these results, showing that a larger filter depth did in fact extract a greater volume of dissolved gas at a faster rate.
| Anchor | ||||
|---|---|---|---|---|
|
| Wiki Markup |
|---|
{float:left|border=2px solid black|width=1100px}
|{anchor:Figure 5}
!Fig. 3, vol vs. time, depths and flow rates.png|width=500px,align=center!
h5. Figure 3: Gas volume vs. time at varying depths and flow rates.|{anchor:Figure 6}
!Fig. 4, vol vs. time, depths adn flow rates 2.png|width=500px,align=center!
h5. Figure 4: Gas volume vs. time at varying depths and flow rates. Excludes results of flow rate = 150 ml/min and depth = 33 cm.|
{float} |
| Wiki Markup |
|---|
{float:right|border=2px solid black|width=400}
{anchor:Table 3}
h5. Table 3: Gas removed by glass beads at varied depths and flow rates
||Bed Depth (cm)||Flow Rate (mL/min)||Slope (mL/min)||Gas Removed (mL/L water)||
|33|200|.6268|3.14|
|10|200|.429|2.15|
|10|150|.3149|1.43|
{float} |
As shown in #Figure 3, the volume of gas removed from the water flowing at 150 mL/min through the 33 cm filter was much greater than that removed at the other flow rates and depths. This was probably because the 33 cm at 150 mL/min run was after the 10 cm runs, which meant we needed to add glass beads to the column. A lot of air came in with the dry beads, and we most likely did not allow sufficient run time afterward in order to allow all the trapped air to escape before we began recording the data. This resulted in the extremely high volumes of gas apparently being removed by our system. By the time we ran that depth at the lower flow rate, the extra air had left and we were gathering only the air being stripped from the water by our filter column.
#Figure 4 shows the same results as #Figure 3 but omits the erroneous 150 mL/min at 33 cm data. Clearly, the greater filter depth resulted in the removal of more dissolved gas than the lower depth. The flow rate was not varied enough to have much impact on the effectiveness of the filter method. Trendlines were once again fitted to the gas volume vs. time curves in #Figure 4, and the resulting gas removals are shown in #Table 3.
| Wiki Markup |
|---|
{float:right|border=2px solid black|width=500px}
{anchor:Figure 5}
!Fig.5, DO red. rate vs. time, no outlier.png|width=500px!
h5. Figure 5: DO reduction rate vs.time at varying depths and flow rates.
{float} |
We also used our Mathcad program to convert the volume of gas we were collecting to an equivalent concentration of dissolved oxygen being removed from the water. #Figure 5 shows the results of this for the three runs shown in #Figure 4. These values for DO removal could not be taken as accurate, however, because the Mathcad program assumes that oxygen is the only gas super-saturating the water. In reality, other gases such as nitrogen could be present. Though the values are not exact, their relative positions on the graph may be used to draw some conclusions.
#Figure 5 shows that the rate of dissolved oxygen removal increased for a short amount of time at the start of each run, but then tended to level off into a steady removal rate as time went on. The higher rate of DO reduction exhibited by the run of the deeper bed depth (33cm) shows again that a deeper bed is more effective.
| Wiki Markup |
|---|
{float:right|border=2px solid black|width=500px}
{anchor:Figure 6}
!DO removed, measured and calculated, 33cm.png|width=500px!
h5. Figure 6: DO removed, measured by the DO probes as well as by calculating equivalent DO using the collected bubble volume. Sand depth of 10 cm, flow rate of 200 mL/min.
{float} |
#Figure 6 compares the DO removal as measured by the DO probes to our calculations using the total collected bubble volume for the 200 mL/min run at 10 cm depth. The graph reveals a large discrepancy between the DO probes' data and the numbers derived from the actual volume of water collected. Again, although the calculated DO-removal values cannot be trusted for accuracy, the overall trend of the numbers can be used for comparison. The negative DO reduction measured by the DO probes would mean that oxygen was added to the water inside the filter column, although the increasing volume of air collected from the water showed that the opposite was true. We concluded from this that our DO probes were definitely not reliable.
The sugar test was performed after several of the runs, but the results varied greatly, even when performed on multiple effluent samples for the same run, or on tap water. Overall, the sugar test results were inconclusive.
Download data for these experiments here
Conclusion
From these results, we may tentatively conclude that greater filter depth removes more dissolved oxygen. However, the method of measuring and recording the volume of gas removed from the water was not precise, and it allowed for a large amount of error and inconsistency. We also cannot be sure that water entering the system was in fact supersaturated, as the temperature outside was growing warmer and varying greatly by the day. As such, we will be able to draw firmer conclusions when the setup includes a method of supersaturating the water and a more accurate and precise method of measuring the collected air volume.
The sugar test proved to be very inconsistent, but it may perform better if a finer sugar is used. This method requires further testing.
After this round of experiments, we altered our setup to include a new bubble collector and a chamber to make sure the water is super-saturated when entering our filter. See the method and results here.