*** This version of Confluence is for testing only and contains a copy of content from June 29th 2026. No changes will be preserved. ***
| Wiki Markup |
|---|
h1. LFOM Entrance Tank Mathcad Code Documentation |
...
h3. Mathcad Code |
...
The mathcad code can be found [here|^EntranceTank 1.xmcd]. You will need to have mathcad installed on your computer in order to open the file. h3. Variable Description: in order of appearance in code ||Variable Name|| Variable Description|| |{latex} $$ N_{Lfom} $$ {latex}|Number of riser pipes| |{latex} $$ K_{Rm} $$ {latex}|minor loss coefficient for rapid mix| |{latex} $$ A_{LfomOrificeTotal} $$ {latex}| Combined area of all orifices| |{latex} $$ A_[Orifice} $$ {latex}|function for determining the orifice areas as the vertical distance on the riser pipe increases| |{latex} $$ HL_[Lfom} $$ {latex}| headloss through the Lfom, and the minimum height of the water in the entrance tank| |{latex} $$ Pi_{VenaContractaOrifice} $$ {latex}|minor loss coefficient for an orifice (was K orifice)| |{latex} $$ Q_{Plant} $$ {latex}|plant flow rate| |{latex} $$ ID_{Lfom} $$ {latex}|the inner diameter of the riser pipe| |{latex} $$ Pi_{LfomOrificeArea} $$ {latex}|ratio of LFOM pipe area to orifice area| |{latex} $$ ND_{Lfom} $$ {latex}|nominal diameter of the riser pipe and rapid mix pipe| |{latex} $$ EN_{PipeSpec} $$ {latex}| enumerated type of pipe| |{latex} $$ HL_{Rm} $$ {latex}| |