Graph of Comparison at 150mL/min:

Image Modified

Conclusion

From this data, we observed that at 100mL/min and 150mL/min the Open Top design produced the lowest turbidity. At 50mL/min, the Parallel Lamella design resulted in the lowest turbidity. Since we care most about how the plant runs at 100mL/min, we determined that the Open Top tank was the best for our purposes.