Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Graph of Comparison at 150mL/min:

Conclusion

From this data, we observed that at 100mL/min and 150mL/min the Open Top design produced the lowest turbidity. At 50mL/min the Parallel Lamella design resulted in the lowest turbidity. However, since we care most about how the plant runs at 100mL/min, we determined that the Open Top tank was the best for our purposes.