Process Controller
Troubleshooting
What to do if you don't see any flocs forming in the settling tube?
*Always check tube connections and make sure there is no clogging in the connections.
*Check the stock solutions. Make sure that there is no sedimentation occurring in clay and alum stock solutions.
*Check the influent turbidimeter. If it displays lower turbidity, then check the clay and alum stock solutions. Check if the flow coming out of the pumps. Check clay/alum flowrates with timer and graduated cylinder. Change in the process controller so that it will give correct value of clay/alum.
*Check bubbles in the floc and settling tubes, especially at the influent of the settling tube. Flocs could get trapped in the bubbles.