Experiment 1: Ramp State with 9.5 mm Plate Settler Tube Diameter
This experiment starts (use past tense in talking about experiment) started with a flow rate of 6 mL/min and over the course of 24 hours, gradually increases increased to a flow rate of 50 mL/min. This flow rate range corresponds to a capture velocity range of approximately 11 m/day to 91 m/day0.127 mm/s to 1.053 mm/s.
Figure 1: Effluent Turbidity vs. Flow Rate
...
This experiment starts with a flow rate of 6 mL/min and gradually increases to a flow rate of 140 mL/min over the course of 24 hours. This flow rate range corresponds to a capture velocity range of approximately 11 m/day to 256 m/day (Put in 0.127 mm/s to 2.963 mm/s units!).
Figure 1: Effluent Turbidity vs. Flow Rate
...