Good thing to note:
#
When setting boundary conditions of the inlet and outlet, they use
Turbulence Specification Method: Intensity and Hydraulic Diameter. (Turbulence intensity, hydraulic diameter)
Use pressure outlet for the outlet boundary condition.
Use adapt --> Gradient -- > deselect coarsen -- >compute -- > enter value for refine threshold -- > mark - >manage.
#

Create a mesh with more elements. Following the same steps, still not quite the same as the tutorial solution.

...