Good thing to note:
#
When setting boundary conditions of the inlet and outlet, they use
Turbulence Specification Method: Intensity and Hydraulic Diameter. (Turbulence intensity, hydraulic diameter)
Use pressure outlet for the outlet boundary condition.
Use adapt -> Gradient --> deselect coarsen -->compute --> enter value for refine threshold --> mark->manage.
#
Create a mesh with more elements. Following the same steps, still not quite the same as the tutorial solution.
...