Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

2nd mesh face using Quad, Submap (interval size 0.005), only Stair steps option are available for mesh volume (interval size 0.001).
Workable. Maybe not... still too long...

Use Quad Submap 0.005, use stair steps 0.005. Get result.

In Fluent:
Use K-e model. Use liquid water. Set inlet = -39.9 in x direction

Got the mesh. Now need to compare.

Mesh 5 is the good one! The velocity vector compares ok with the data. The difference might be due to our mesh not refine enough causes truncation error.