| Include Page |
|---|
| AGUACLARA: A.Et |
|---|
| AGUACLARA: A.Et |
|---|
|
The depth of the entrance tank is designed to have the same depth as the floc tank, plus a depth to account for the headloss through the linear flow orifice meter.
| Include Page |
|---|
| AGUACLARA: ZW.Et |
|---|
| AGUACLARA: ZW.Et |
|---|
|
| Include Page |
|---|
| AGUACLARA: H.Et |
|---|
| AGUACLARA: H.Et |
|---|
|
Grit Chamber
The grit chamber is contained within the entrance tank. A concrete barrier will be built to give the grit chamber a length that satisfies the upward velocity constraint.
{include:Note that the width of the entrance tank is defined to be the same width as a floc channel.
| Include Page |
|---|
| AGUACLARA: L.Grit |
|---|
| AGUACLARA: L.Grit |
|---|
|